Library guide
Library guide
This page summarizes what a library for driving the display must provide – independent of the programming language. The .NET reference implementation implements it.
Layers
flowchart TB
App["Application / service<br/>(read sensors)"] --> Session
Session["Session / keep-alive<br/>Timer 250 ms, reconnect, off on exit"] --> Device
Device["Device<br/>Find, open, 65-byte write, error → disconnect"] --> HID["HID backend<br/>hidraw · hidapi · Windows HID"]
Session --> Codec["Codec (pure, no I/O)<br/>Frame → 64-byte packet"]
| Layer | Responsibility | Testability |
|---|---|---|
| Codec | values → 64 bytes per update packet, off packet | fully unit-testable with the test vectors |
| Device | VID/PID search, opening, prepending the report ID, write with timeout | against real device / mock |
| Session | periodic sending, atomic swap of the current frame, hotplug | with fake device |
Requirements
Detection
- Only address known VID/PID pairs (
5131:200e,5131:2007). Vendor0x5131is also used for unrelated devices – never write to “all devices of 0x5131”. - Additionally check: HID interface with output report length 64 (or 65 including report ID).
- No serial number available → distinguish multiple devices by their physical path.
- Missing product/manufacturer strings are not an error.
Sending
- Send every packet completely (64 bytes); via hidraw/hidapi/Windows with report ID
0x00prepended (65 bytes). - Interval 250 ms by default, configurable, but at most 400 ms – the display turns off after approx. 400–500 ms without a packet.
- The sending thread must not be blocked by slow sensors: read sensors at their own pace and place the last valid frame into the session atomically.
- One writer per device (mutex or similar). Two processes on the same device cause flickering.
- Fill the time fields with the current local time in every packet.
Errors & hotplug
| Situation | Behavior |
|---|---|
| Device not present at startup | rescan periodically (e.g. every second) or use a udev monitor |
| Opening fails with “access denied” | clear message pointing to the udev rule; do not log in an endless loop |
Write fails (ENODEV, EPIPE, I/O error) | close handle, state “disconnected”, reconnect |
| Write timeout | retry once, then treat as an error |
Exit (Dispose, SIGTERM, service stop) | stop timer, send off packet, close handle |
| System suspend | reconnect after resume (device is often re-enumerated) |
Recommended API
Frame – immutable set of values (nullable fields, temperatures always in °C, unit separate)
encode_update(frame, now) -> bytes[64]
encode_off() -> bytes[64]
enumerate() -> [DeviceInfo] # without opening (works without permissions)
open(info) -> Device
Device.send_packet(bytes[64])
Session(connect_fn, interval)
Session.update(frame) # thread-safe
Session.start() / Session.close(send_off = true)
events: connected(path), disconnected, packet_sent(bytes)Non-goals
- Controlling fan/pump (handled via the motherboard headers).
- ARGB lighting (handled via the 5 V ARGB header).
- Sensors in the library itself – better as a plug-in/callback so that the library stays platform-neutral.
Platform backends
| Platform | Backend | Notes |
|---|---|---|
| Linux | hidraw directly (open/write/poll) | no dependencies, details |
| Linux / Windows / macOS | hidapi (libhidapi-hidraw, hidapi.dll) | native library required |
| .NET | HidApi.Net (AOT-capable binding for hidapi) | used in the reference, requires native hidapi |
| .NET | HidSharp (fully managed, Linux via hidraw + libudev) | no native dependencies, but trim warning under AOT |
| Windows native | CreateFile on interface path, WriteFile with 65 bytes | path via SetupAPI/HidD_GetHidGuid |