Input reports
According to the HID descriptor, the device can send 64-byte input reports via the interrupt IN endpoint 0x81.
The original software (LA series) never reads them; their meaning is unknown.
Possible contents (speculation, to be checked): firmware version, acknowledgment (ACK) of received packets, buttons/touch (the LB360-S display has no known controls).
Investigation
# listen for 30 s without sending anything
seglcd listen --duration 30
# listen while update packets are being sent (in case the device only responds then)
seglcd listen --keep-alive --duration 30On Linux, read() on hidraw returns the 64 bytes without report ID for unnumbered reports;
hidapi (hid_read, HidApi.Net ReadTimeout) also returns 64 bytes without report ID; HidSharp, in contrast, returns 65 bytes with a leading 0x00.
A library does not need to read input reports. The kernel buffers up to 64 reports per open hidraw file descriptor
and then discards the oldest ones – an overflow therefore does no harm.