Skip to content
Off packet (0F)

Off packet (0F)

The original software sends this packet once on exit; the display then goes dark.

OffsetValueContent
00x00reserved
10x0Fcommand “off”
2–630x00–
00 0f 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

Notes for implementations:

  • The off packet is optional: on the LB360-S the display also turns off about 400–500 ms later without 0F, as soon as no more update packets arrive (timeout, verified with seglcd hold). The packet merely makes turning off explicit.
  • After an off packet, a new update packet is enough to turn the display back on (observed on the LA series).
  • The TT SEGMENT LCD Software for the LB360-S does not send 0F on exit (capture 2026-11-20) – it relies on the timeout. The statement “original sends 0F” comes from the LA software.
  • Recommendation nonetheless: send it on orderly shutdown (service stop, SIGTERM, Ctrl+C); it does no harm and turns the display off without delay. In case of a crash, the timeout takes over.