Inline assembler
Before this page you should know labels and constants (The language, Types, variables and constants).
The compiler has a 68000 assembler built in. A line of a program can hold 68000 instructions instead of Basic statements, or both, separated by colons; the compiler assembles each instruction at the place where it stands, between the code of the statements around it. There are three ways to use it:
- Inline, in the middle of the program, with
GetRegandPutRegto move values between Basic expressions and the registers. This page describes it. - In a procedure made entirely of assembler, which gets its parameters in registers (Procedures in assembler).
- In a library of your own, whose commands can be used like any other (Writing your own library).
Registers the program needs
Three address registers belong to the program, and assembler code must
give them back with their old values: a5 points to the global variables,
a4 to the local variables of the current procedure, and a6 holds a
library base the compiler may still use. All other registers are free,
but they keep nothing for you between two Basic statements: any
statement may change them. Values go in and out with GetReg and
PutReg.
GetReg and PutReg
GetReg register,expression computes the expression as a Long and puts
the result into the register, any of d0 to d7 or a0 to a7. All other
registers keep their values. PutReg register,variable stores the
register in the variable and changes no register:
a.w=5
b.w=10
GetReg d0,a
GetReg d1,b
MULU d0,d1
PutReg d1,c.w
NPrint c ; 50The variable of PutReg can be a plain variable, an array element or a
field of a NewType, such as PutReg d0,list(3) or PutReg d0,pos\x.
The store follows its type: a Byte gets the low byte of the register, a
Word the low word, every other type all 32 bits. A Quick or Float
variable gets those bits as they are, without conversion: a 1 in the
register is not the Quick 1, which is $10000. Do not use PutReg with
a string variable: the compiler accepts it, but the register overwrites
the variable’s reference to its text.
Instructions
The assembler knows the instructions of the 68000 and no others:
The instructions
ABCD ADD ADDA ADDI ADDQ ADDX AND ANDI ASL ASR
BCC BCS BEQ BGE BGT BHI BLE BLS BLT BMI BNE BPL
BVC BVS BCHG BCLR BSET BTST BRA BSR CHK CLR CMP
CMPA CMPI CMPM DBCC DBCS DBEQ DBGE DBGT DBHI DBLE
DBLS DBLT DBMI DBNE DBPL DBVC DBVS DBF DBRA DBT
DIVS DIVU EOR EORI EXG EXT ILLEGAL JMP JSR LEA
LINK LSL LSR MOVE MOVEA MOVEM MOVEP MOVEQ MULS MULU
NBCD NEG NEGX NOP NOT OR ORI PEA RESET ROL ROR
ROXL ROXR RTE RTR RTS SBCD SCC SCS SEQ SGE SGT
SHI SLE SLS SLT SMI SNE SPL SVC SVS ST SF STOP
SUB SUBA SUBI SUBQ SUBX SWAP TAS TRAP TRAPV TST
UNLK
The other names some assemblers have for the same conditions, such as
BHS and BLO, are not among them: write BCC and BCS. Like every
word the compiler knows, an instruction can be typed in any case; the
editor shows it in capitals.
The size follows the instruction as .b, .w or .l; without one, an
instruction works on a word. .s is the same as .b. A size the
instruction does not have, such as MULU.l, is the compile error
“Illegal Assembler Instruction Size”.
ADD, SUB, CMP, AND, OR, EOR and MOVE choose their special
forms themselves: with an immediate source ADD becomes ADDI, with an
address register as destination ADDA, and so on. MOVEQ, ADDQ and
SUBQ must be written as such.
Operands
An operand is written in one of the 68000’s addressing modes:
| Form | Example | Meaning |
|---|---|---|
Dn | d0 | data register d0 to d7 |
An | a0, sp | address register a0 to a7; sp is a7 |
(An) | (a0) | the memory a0 points to |
(An)+ | (a0)+ | the same, then a0 is moved on |
-(An) | -(a0) | a0 is moved back, then the memory it points to |
d(An) | 8(a0) | a0 plus a displacement of -32768 to 32767 |
d(An,Xn) | 4(a0,d1.l) | a0 plus a displacement of -128 to 127 plus an index register, as .w (the default) or .l |
d(PC) | table(pc) | a label, reached relative to the instruction |
d(PC,Xn) | table(pc,d0.w) | the same with an index register |
| address | table, 4 | an absolute address, a label or a number, as a long |
#value | #10 | an immediate value |
| register list | d0-d3/a0 | the registers of MOVEM |
sr, ccr, usp | MOVE d0,ccr | the status register, its low byte, the user stack pointer |
sp is accepted only as a register on its own; inside brackets write
a7, as in -(a7). An absolute address is always a long: the short
form with .w or .l after the address is a “Syntax Error”.
A value in an operand is a constant expression: numbers, constants and
labels with the operators of Basic, and character constants of up to four
characters in quotes, such as #"ABCD". A name stands for a label, and
its value is the label’s address. Because constants and labels share their
names, a constant can be written with or without its #: after
#width=320, both MOVE #width,d0 and MOVE ##width,d0 load 320. A
name that is neither, such as the name of a variable, is the compile error
“Constant Not Found”; the ? in front of a label is for Basic
expressions only and is a “Syntax Error” in an operand.
The compiler works the values out at the end of the compile, so a label
may stand further down the source. Values that do not fit are compile
errors: a displacement out of its range is “Illegal Displacement”, and
so is a MOVEQ value outside -128 to 127; an ADDQ, SUBQ or shift
count outside 1 to 8 is “Illegal Immediate Value”, a TRAP number above
15 “Illegal Trap Vector”. An immediate value of a byte or word
instruction is not checked: its low byte or word is used.
Labels and branches
A label in assembler is an ordinary label of the program. BRA, BSR,
the Bcc and the DBcc instructions branch to a label, and JMP,
JSR, LEA and PEA take one as an address:
MOVEQ #5,d0
BSR addone
PutReg d0,v.l
NPrint v ; 6
End
addone:
ADDQ #1,d0
RTSA label must not be a word the editor knows: a label sub becomes the
instruction SUB, and the line gives an error.
A branch is a word branch of 4 bytes. With the size .s or .b it is a
short branch of 2 bytes, which reaches 128 bytes back and 126 bytes
ahead. The short branch is an addition of the port; the
Extensions
page has the details.
Local labels keep the names of small loops apart. A label that begins with an apostrophe belongs to the last ordinary label before it, and an operand that begins with an apostrophe means that local label:
Dim buf.w(9)
.fill
GetReg a0,&buf(0)
MOVEQ #9,d1
'loop
MOVE.w d1,(a0)+
DBRA d1,'loop
NPrint buf(0)," ",buf(9) ; 9 0'loop here is fill'loop, so another part of the program can have a
'loop of its own under another label. A local label with no ordinary
label before it is the compile error “Illegal Local Name”.
Data: Dc, Ds and Dcb
These statements put data into the program at the place where they
stand. The size is .b, .w or .l; without one it is .w.
Dcwrites values:Dc.w 10,20,30. A value is a constant expression or a label, whose addressDc.lwrites.Dc.balso takes text in quotes, as the bytes of its characters:Dc.b "Name",0. The backslash is an ordinary character there.Dsreserves room:Ds.l 4is 16 bytes, all 0.Dcbwrites one value several times:Dcb.w 8,-1is eight words of -1. A count of 0 writes nothing; a negative count is the compile error “Illegal Constant”.
Dc.w, Dc.l, Dcb.w and Dcb.l first move to an even address, as a
word or long of the 68000 needs. After byte data, Even moves to the
next even address, Even4 to the next multiple of 4 and Even8 to the
next multiple of 8, with bytes of 0 in between. A label for the aligned
data goes after the Even, not before it.
The program runs through these lines as through any other: data in the
middle of the program would be executed as instructions. Put the data
after End, or jump over it, and reach it with its label:
Goto start
.table
Dc.w 10,20,30
.start
NPrint Peek.w(?table+2) ; 20IncBin puts the bytes of a whole file into the program in the same
way (Include files).
Calling library routines
TokeJsr command[,form] calls the routine of a library command directly.
The command is given by its name or by its token number, which is the
library number times 128 plus the command’s place in the library. A
command with several forms has one routine per form; form chooses one,
counted from 0. The routine takes its arguments in d0, d1 and so on, as
the compiler would put them there, and returns its result in d0
(How arguments arrive):
MOVEQ #0,d0 ; port 0
TokeJsr Joyb
PutReg d0,b.l ; the buttons pressed on port 0
NPrint bThe library of the command goes into the program as if the command were
used. After BLITZ the call goes to the routine’s Blitz mode version, if
the command has one. A number that is no command is the compile error
“Token Not Found”, with the number; a built-in word of the compiler, or a
value that is not a whole number from 0 to 65535, is “Illegal TokeJsr
token number”.
SysJsr number calls a routine of the runtime libraries, the libraries
without commands that the compiler calls by itself, by its internal
number. These numbers are not documented for programs; SysJsr is meant
for writing libraries.
ALibJsr command[,form] and BLibJsr command[,form] are for the source
of a Blitz library only. They leave a call to the routine of another
library’s command that the compiler completes when it copies both
libraries into a program: ALibJsr to the Amiga mode version of the
routine, BLibJsr to the Blitz mode version. In a program, nothing
completes the call, and it leads nowhere. The libraries of the port are
written in C and make these calls with a macro
(Calling other libraries).
In AB3 mode
In AB3 mode the inline assembler
works as described here, with two differences. A branch with .s or
.b stays a word branch, as in AmiBlitz3
(Other additions).
Text in Dc.b has the date and version escapes of AmiBlitz3
(Escapes in strings).
As in BB2 mode, only the 68000’s instructions are assembled, not
those of the 68020 that AmiBlitz3 knows
(68020 code).
Based on the Blitz Basic 2 manual by Acid Software. The manual says that
GetReg should only be used with data registers; the compiler loads
address registers as well.